Fluorescent Microspheres
|
|

|
Catalog
|
Photostable fluorescent microspheres have been developed and patented by our department. These polystyrene microspheres are monodisperse and uniform, ranging from 0.1µm to 4 µm and are also available as plain or functionalized microspheres. These fluorescent microspheres contain a variety of dyes, spanning the visible spectrum from UV (Excitation wavelength = 375nm/ Emission wavelength = 435nm) to red (Excitation wavelength. = 420nm / Emission wavelength = 660nm)
Our Fluorescent Microspheres are supplied at 1% concentration in water (100mg/10ml).
|
|

|
Underlined wavelengths represent predominant excitation and emission wavelengths.
X is excitable at the 442nm He-Cd laser line.
XC and Y are well suited to the 488nm and 515nm bands of the Argon laser.
Fluorescent Standard Microspheres for Flow Cytometer
New type of Fluorescent and Monodisperse Microspheres have been developed and patented.Kits,containing those new products, are designed for the routine calibration and control for flow cytometry.
The fluorescent particles have a long term photo-stability and are supplied as ready-to-use reagents.
|
ESTAFOCUS
Kit for aligning and focusing flow cytometers
• Size of particles : 2 – 2.5 µm
• Argon-ion laser excitation : 488 nm
• Emission range : 500 – 660 nm
• CV fluorescence : < 2 %
|
|
 |
 |
|
ESTACAL
An intensity calibration kit (different beads suspensions of various % relative fluorescent intensities) recommended for calibrating.
• Size of particles : 2 – 2.5 µm
• Argon-ion laser excitation : 488 nm
• Emission range : 500 – 660 nm
• CV fluorescence : < 4 %
|
|
ESTACOLOR
Kit for aligning flow cytometers at different wavelengths.
|
|
 |
|
l Excitation (nm)
|
|
l Emission (nm)
|
|
360
|
|
450
|
|
488, 514
|
|
585 - 610
|
|
360, 488, 514
|
|
560 - 670
|
|
|
Dye
|
l Excitation Wavelength (nm)
|
l Emission (nm)
|
Color
|
|
U
|
Scintillator or eventually photoescitable at 375
|
|
White
|
|
X
|
440, 455, 468
|
480, 510
|
Yellow
|
|
XC
|
470, 490
|
525, 560
|
Pink
|
|
Y
|
515, 555
|
568, 610
|
Red
|
|
Z
|
420, 515, 550
|
656, 720
|
Red
|
|
Plain Polystyrene Fluorescent Microspheres
|
Top
|
|
Product#
|
Diameter (µm)
|
Polymer
|
Catalog No
|
|
F-U010
|
0,076-0,125
|
Polystyrene
|
80 380 066
|
|
F-U030
|
0,276-0,325
|
Polystyrene
|
39 410 088
|
|
F-U050
|
0,476-0,575
|
Polystyrene
|
80 380 067
|
|
F-U100
|
0,900-1,100
|
Polystyrene
|
80 380 068
|
|
F-U200
|
1,800-2,200
|
Polystyrene
|
39 557 001
|
|
F-U300
|
2,700-3,300
|
Polystyrene
|
80 380 069
|
|
F-X010
|
0,076-0,125
|
Polystyrene
|
39 373 080
|
|
F-X050
|
0,476-0,575
|
Polystyrene
|
39 555 001
|
|
F-X100
|
0,900-1,100
|
Polystyrene
|
80 380 070
|
|
F-X200
|
1,800-2,200
|
Polystyrene
|
80 380 071
|
|
F-X300
|
2,700-3,300
|
Polystyrene
|
80 380 072
|
|
F-XC010
|
0,076-0,125
|
Polystyrene
|
39 558 001
|
|
F-XC030
|
0,276-0,325
|
Polystyrene
|
39 377 083
|
|
F-XC050
|
0,476-0,575
|
Polystyrene
|
80 380 073
|
|
F-XC100
|
0,900-1,100
|
Polystyrene
|
80 380 009
|
|
F-XC200
|
1,800-2,200
|
Polystyrene
|
39 560 001
|
|
F-XC300
|
2,700-3,300
|
Polystyrene
|
39 561 001
|
|
F-Y010
|
0,076-0,125
|
Polystyrene
|
80 380 074
|
|
F-Y030
|
0,276-0,325
|
Polystyrene
|
39 379 080
|
|
F-Y200
|
1,800-2,200
|
Polystyrene
|
39 562 001
|
|
F-Y300
|
2,700-3,300
|
Polystyrene
|
39 563 001
|
|
F-Z010
|
0,076-0,125
|
Polystyrene
|
80 380 075
|
|
F-Z030
|
0,276-0,325
|
Polystyrene
|
80 380 076
|
|
F-Z050
|
0,476-0,575
|
Polystyrene
|
80 380 077
|
|
F-Z100
|
0,900-1,100
|
Polystyrene
|
80 380 078
|
|
F-Z 200
|
1,800-2,200
|
Polystyrene
|
39 564 001
|
|
F-Z 300
|
2,700-3,300
|
Polystyrene
|
39 565 001
|
COOH-Modified Fluorescent Microspheres
|
Product#
|
Diameter (µm)
|
Polymer
|
Catalog No
|
|
F1-U010
|
0,130-0,190
|
Polystyrene
|
39 396 088
|
|
F1-U030
|
0,270-0,330
|
Polystyrene
|
39 371 083
|
|
F1-U050
|
0,450-0,530
|
Polystyrene
|
80 380 079
|
|
F1-U080
|
0,760-0,940
|
Polystyrene
|
39 411 082
|
|
F1-U100
|
0,950-1,100
|
Polystyrene
|
80 380 080
|
|
F1-X010
|
0,130-0,190
|
Polystyrene
|
39 374 083
|
|
F1-X030
|
0,270-0,330
|
Polystyrene
|
39 412 085
|
|
F1-X050
|
0,450-0,530
|
Polystyrene
|
39 566 001
|
|
F1-X080
|
0,760-0,940
|
Polystyrene
|
39 413 088
|
|
F1-X100
|
0,950-1,100
|
Polystyrene
|
80 380 081
|
|
F1-XC010
|
0,130-0,190
|
Polystyrene
|
80 380 082
|
|
F1-XC030
|
0,270-0,330
|
Polystyrene
|
39 414 082
|
|
F1-XC050
|
0,450-0,530
|
Polystyrene
|
39 566 001
|
|
F1-XC080
|
0,760-0,940
|
Polystyrene
|
39 415 085
|
|
F1-XC100
|
0,950-1,100
|
Polystyrene
|
80 380 029
|
|
F1-Y010
|
0,130-0,190
|
Polystyrene
|
39 378 086
|
|
F1-Y030
|
0,270-0,330
|
Polystyrene
|
39 416 088
|
|
F1-Y050
|
0,450-0,530
|
Polystyrene
|
39 566 001
|
|
F1-Y080
|
0,760-0,940
|
Polystyrene
|
80 380 083
|
|
F1-Y100
|
0,950-1,100
|
Polystyrene
|
80 380 084
|
|
F1-Z010
|
0,130-0,190
|
Polystyrene
|
39 419 088
|
|
F1-Z030
|
0,270-0,330
|
Polystyrene
|
39 420 083
|
|
F1-Z050
|
0,450-0,530
|
Polystyrene
|
80 380 085
|
|
F1-Z080
|
0,760-0,940
|
Polystyrene
|
39 567 001
|
|
F1-Z100
|
0,950-1,100
|
Polystyrene
|
80 380 029
|
ESTACOLOR
Kit for aligning flow cytometers at different wavelengths
|
l Excitation (nm)
|
l Emission (nm)
|
|
360
|
450
|
|
488, 514
|
585 - 610
|
|
360, 488, 514
|
560 - 670
|
|
|